Salt Spray Corrosion Chamber used to test the corrosive resistance of products whose the surface was treated with paint, electroplating, inorganic and organic film, anode handling, anti-rust oil, etc.
3. Air supply system: air pressure 1Kg/cm2 Two-stage adjustments (coarse / fine-tuning).
The first paragraph for the rough adjustment 2-2.5Kg/cm2, the second paragraph to fine-tune 1Kg/cm2.
Testing configuration is switch connector designed for SO2.
4. Spray form:
Using Bo Nute principle to draw brine and then saline spray, atomization uniform, non-blocking and crystallization, so that ensure continuous spraying.
Nozzle: The nozzle is made of special glass, adjust spray volume and spray angle.
5. Heating devices:
By direct heating, warming up faster and reduction of standby time, when the temperature arrives automatically switch ON / OFF, make temperature accuracy, low power consumption (heating tube is made of titanium alloy).
6. The control system:
Testing room temperature controller is the digital micro-computer products 0-99.9 ℃, liquid crystal digital display with PID automatic calculation, the control error is ± 0.3 ℃ (YANG MING6802) 1 pcs.
Saturated air barrels controller 0 ~ 99.9 ℃, liquid crystal digital display with PID automatic calculation, the control error is ± 0.3 ℃ (YANG MING6802) 1 pcs.
Safe temperature controller of heat expansion of the liquid tank 30 ~ 110 ℃ (Italy) 1 pcs.
Safe temperature controller of expansion of the saturated air barrel : 30 ~ 110 ℃ (Italy) 1 pcs.
Digital time controller 9.9s ~ 9990hr (Taiwan) 1 pcs.
Timer 0 ~ 9999hr (Taiwan Anliang) 1 pcs.
Buckle switch, continuous buckling 20000 times.
Pressure gauge, (Taiwan B card).
Fixture bleaker (YANG MING).
Electromagnetic valve; (KSD).
Regulating valve (YIHUA).
Bleaker (Omron).
Technical parameter
Model
HZ-2001A-108L
HZ-2001A-270L
HZ-2001A-480L
Inside box size(cm)
60x45x40
90x60x50
120x80x50
Outside box size(cm)
107x60x118
141x88x128
190x110x140
Testing room temperature
Salt test (NSS ACSS)35℃±1℃/ Corrosion Test (CASS)50℃±1℃
Pressure barrel temperature
Salt test (NSS ACSS)47℃±1℃/ Corrosion Test (CASS)63℃±1℃
Brine temperature
35℃±1℃ 50℃±1℃
Testing room Capacity
108L
270L
480L
Brine tank capacity
15L
25L
40L
Salt concentration
The concentration of sodium chloride 5% or the 5% concentration of sodium chloride add 0.26g per liter of copper chloride (CuCl2 2H2O)
Air pressure
1.00±0.01kgf/cm2
Testing room relative humidity
85% above
PH
6.5~7.2 3.0~3.2
Spray form
Programmable spray (Including continuous and intermittent spray)
power
AC220V1Φ10A
AC220V1Φ15A
AC220V1Φ20A
Corresponding standard:
GB/T 2423.17-1993 salt spray test
GB/T 2423.18-2000 salt spray test
GB/T 10125-1997 salt spray test
ASTM.B117-97 salt spray test
JIS H8502 salt spray test
IEC68-2-11 salt spray test
IEC68-2-52 1996 salt spray test
GB.10587-89 salt spray test
CNS.4158 salt spray test
CNS.4159 CASS Accelerated acetic acid copper salt spray test
GB/T 12967.3-91 CASS Accelerated acetic acid copper salt spray test
ASTM B117 Standard Practice for Operating Salt Spray (Fog) Apparatus